System Management Commands
4-55
4
sntp poll
This command sets the interval between sending time requests when the switch is
set to SNTP client mode. Use the no form to restore to the default.
Syntax
sntp poll seconds
no sntp poll
seconds - Interval between time requests. (Range: 16-16384 seconds)
Default Setting
16 seconds
Command Mode
Global Configuration
Example
Related Commands
sntp client (4-53)
show sntp
This command displays the current time and configuration settings for the SNTP
client, and indicates whether or not the local time has been properly updated.
Command Mode
Normal Exec, Privileged Exec
Command Usage
This command displays the current time, the poll interval used for sending
time synchronization requests, and the current SNTP mode (i.e., unicast).
Example
Console(config)#sntp poll 60
Console(config)#
Console#show sntp
Current time: Dec 23 05:13:28 2002
Poll interval: 16
Current mode: unicast
SNTP status : Enabled
SNTP server 137.92.140.80 0.0.0.0 0.0.0.0
Current server: 137.92.140.80
Console#

Table of Contents

Other manuals for SMC Networks SMC8126L2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks SMC8126L2 and is the answer not in the manual?

SMC Networks SMC8126L2 Specifications

General IconGeneral
BrandSMC Networks
ModelSMC8126L2
CategorySwitch
LanguageEnglish

Related product manuals