1-34 (E)
VPL-FHZ55
1-5. Optional Fixtures
1-5-1. Extension Boards and Extension Cables
n
. The laser diode is used as a light source of this unit.
Never allow the light source to emit light with the cabinet removed.
Otherwise, it may cause damage to eyes or skin.
. Do not remove the lens when the set is lighting.
Otherwise, it may cause damage to eyes or skin.
. Do not release the protection switch with the cabinet removed.
Otherwise, the light source may suddenly start emitting light, causing damage to eyes or skin.
. In order to avoid inappropriate use of the laser diode, do not disassemble the laser unit assembly LEO.
A Flexible flat cable 57P (C board to XF57 board) x3
XC board
XF57 board x3
B Flexible flat cable 24P (X70 board to X70 board) x6
E Cable 14P (C board to XC board) x1
G Cable 12P (C board to XC board) x2 (1 mm pitch)
I Cable 112P (C board to XC board) x1 (2 mm pitch)
H Cable 110P (C board to XC board) x2
C Cable 12P (C board to XC board) x1
D Cable 13P (C board to XC board) x3
F Cable 17P (C board to XC board) x2
J Cable 16P (C board to XC board) x2
XL board x1
(For “2-4. Adjustment of Laser Luminance and
Luminance Sensor”)
X70 board x4
SERVICE KIT ASSEMBLY (A-1970-760-B)