2-2 (E)
VPL-FHZ55
2-2. Preparation for Electrical Adjustment
2-2-1. Required Equipment
. NTSC, PAL, SECAM component signal generator:
Tektronix TG2000 + AVG1 (option module) + AWVG1 (option module) or equivalent
. VG (programmable video signal generator):
ASTRODESIGN VG-828 or equivalent
. Chroma meter:
KONICA MINOLTA CL-200 or equivalent
n
Allow the warm-up time of 5 minutes after the power is on before starting the V com and White balance
adjustments.
2-2-2. How to Enter the Service Mode
1. Press the [MENU] key.
The menu appears.
2. Set the Status to “On” in the Operation menu.
3. Press the [MENU] key to close the MENU.
4. Press the keys in the following order:
[ENTER] → [ENTER] → [&] → [ENTER]
The message “Do you want to enter the Service Mode? [Yes] [No]” appears.
Select [Yes] and press the [ENTER] key.
How to exit the service mode
Perform the key operations in accordance with step 4.
The message “Do you want to return to the User Mode? [Yes] [No]” appears.
Select [Yes] and press the [ENTER] key.
2-2-3. How to Enter the Model Name Display (Shop Demonstration) Mode
1. Set the “Status” to “On” in the “Setup” MENU.
2. Close the menu by pressing [MENU] button if its displayed.
3. Press the buttons in the following order in 5 seconds:
[ENTER]→ [(] → [)] →[ENTER]
Demonstration mode screen is displayed.
t
Even if the message “Not applicable!” is displayed, ignore it. If the key operations failed, wait for at
least 6 seconds since the last key is pressed, and perform the key operations again.
4. Select “Model Name Display”.
n
To exit the Model Name Display mode, perform step 3. “Demonstration mode screen” is displayed. Select
“Off”.