FITTED EQUIPMENT
158
Operation with batteries
(internal power supply)
Indicator Fault Remedy
(3) and (8)
flashing brightly
Flame not ignited Check gas supply (gas bottle, gas valve)
Press the (8) button after clearing the fault
(3) and (7)
flashing brightly
Burner defective
or cooling unit
defective
Check burner, burner nozzles, if necessary
contact Customer Service and arrange
replacement
Acoustic signal at
15 second intervals
Undervoltage
detection (internal
batteries)
Replace batteries
Automatic
switching from
external to internal
power supply
does not function
(absence of the
onboard 12V power
supply for the
electronics)
Refrigerator does
not function, gas
operation not
possible although
the batteries are
inserted
Switch off the refrigerator and start again
The onboard power supply was interrupted during
the starting of the gas operation
Note: No automatic switching is performed during
the ignition.
DOMETIC REFRIGERATOR TROUBLESHOOTING