PLUMBING TROUBLESHOOTING
Troubleshooting
Pump will not start, when the tap is
opened:
• Check fuse(s).
Check power source(s), and ensure there is
sufficient voltage to run the pump.
• Ensure 'pump' LED is illuminated.
Using a multi-meter, ensure there is power at
the pump. If not, refer to your dealer as there
maybe damaged cabling or a fault with the
fusebox.
Is the pump hot? If so, allow to cool
before retrying.
Has the vehicle been stored over winter?
Was it correctly winterised? If no, the pump
may have frozen, causing permanent
damage.
The pressure switch may need adjusting.
See page 62 on how to do this.
Pump runs, but will not pressurise system
(i.e. no or little water being discharged
from taps) - Not Pulsing:
Ensure water in source is present (onboard
tank or aqua roll).
Check in-line pump filter is free from debris
and correctly fitted.
Ensure water system has been primed
correctly, (see pages 57 and 59) and there
are no air-locks present.
Ensure there are no restrictions
in the plumbing.
Using a multi-meter, ensure there is power at
the pump. If not, refer to your dealer as there
maybe damaged cabling or a fault with the
fusebox.
Ensure the inlet side of the pump (including
Truma inlet and in-line filter)
are watertight and not allowing air into
the system.
Ensure the pump has good voltage.
Check (using a mulitmeter) that the voltage
at the pump is between 10v-14.5v.
Pump continues to run (for more than 5
seconds) after taps are closed or pump
turns on for no reason:
Check for leaks on the high pressure side of
the pump.
Ensure water system has been primed
correctly, (see pages 57 and 59) and there
are no air-locks present.
Ensure the pump is securely mounted.
Ensure the piping on the high pressure side
of the pump is in good condition (not blowing
or deforming).
The pressure switch may need adjusting.
See page 62 for information on how to do
this.
Noisy or rough operation
Check for leaks on the high pressure and low
pressure side of the pump.
Ensure that all pipes (especially those within
150mm of the pump) are not touching any
furniture.
Ensure the pump is securely mounted.
Pump rapidly cycles (switches on or off)
or water pulses from taps, including tem-
perature pulsing:
Check for leaks on the high pressure and low
pressure side of the pump.
Ensure there are no restrictions in the
plumbing
The pressure switch may need adjusting.
See Section (page 62) for information on
how to do this.