ELECTRICALREQUIREMENTS
AllSynesso™machinesareratedtooperateon220vACwitha50or60Hzfrequency,singlephase.Machines
willoperatebetween208vand240v.
Listedamprangsareallmeasuredat220v.Incorrectvoltagecancausemalfunconordamagetothema‐
chine.
Anelectricalsocketandmatchingplug,ratedatthepropervoltageandamperagearerequiredwithinthree
feetofthemachine.PlugendsareNOTincludedwiththemachineunlessrequiredbyCSAorothercerfica‐
on.
Aachtheplugendpermanufacturer’sinstrucons.
Makesure
thattheredelectronicsswitchandtheheangelementbreakeronthefrontoftheelectricalbox
areintheOFFposion,thenplugthepowercordintothereceptacle.
OPTIONAL:Ifrecoverymeisslow,installanIn‐LineBuck‐Boosttransformertoincreasevoltagebelow208v
toopmizemachinerecoveryme.Buck‐boosttransformerscomeindifferentsizes.Pleasechoosetheap‐
propriateoneforyourmachineifrequired.1and2GroupMachinesrequirea1.0KVAtransformer,3Group
Machinesrequirea1.5KVAtransformer.
SPECIAL ELECTRICAL INFORMATION FOR EMC‐COMPLIANT MACHINES
(C‐TICKFORAUSTRALIA,CEFOREUROPEANDOTHERLOCATIONS)
TocomplywithEMC(ElectromagnecCompability)regulaons,Synesso™isrequiredtoinstallacapacitor
intheelectronicsboxacrossthemainpowerIN.To avoid an electric shock from the charge held in the ca‐
pacitor, unplug the cord, taking care to NOT touch the metal prongs on the plug end. Turn the electronics
ON/OFF red rocker switch to the ON posion and wait a few seconds unl the red switch “goes dark.” At
that point, the electrical charge has dissipated.
North American Wire Color
Green Ground GreenandYellow Ground(Earth)
White 110vLine1 Brown 220v
Black 110vLine
2 Blue Neutral
Worldwide Wire Color
Model CordPlugRang(ULListed) MachineMaxAmpDraw
2GroupMVP 30amp 28amp
3GroupMVP 50amp 36amp
1GroupMVPHydra 20amp 16amp
2GroupMVPHydra 30amp 30amp
3GroupMVPHydra 50amp 40amp