20
PROGRAMMING
Line1ofthefirstbrewgroupcontrolscreenindicatesthecurrenttemperatureofthebrewtankasmeasured
byitsprobe.Oncethistemperaturereachesthesetpoint,itwillconnuouslycycleupanddownbysmall
incrementsastheelectronicsbalancethetemperature.Thislinealsoindicates
theacveprogram(PRG1in
thiscase).Changingtheacveprogramwillupdatethesengsonlinesbelow.
Line2isindicangthesetpointof202.0F(94.4C).
Line3indicatesthelengthofmepre‐infusionissetforinthecurrentprogram.WhenstarngashotinMP
orVPmode,pre‐infusionwillallowlinepressurewatertosoakthepuckforaslongasindicatedbeforemov‐
ingontothenextbrewphase.Sengthepre‐infusionmedownto0.0secondswillskipthepre‐infusion
phaseinMP
andVPmodes.Onesteplowerthan0.0isthe“MAN”seng,whichwillrequiretheoperatorto
exitthepre‐infusionphasemanuallyinMPmode,andwillskippre‐infusioninVPmode.
Line4indicatesthelengthmesetfortheramp‐upphaseinthecurrent
program.ThisoponwillONLYbe
visibleonMVPHydramodels.Ramp‐upmebeginsoncethepre‐infusionstagehasfinished.
Tocycletothenextdisplayscreen,pressthedownbuon.
Menu Level 1: Group 1, Program 1
Factory Sengs:
Thefactorysengsforyourmachineareasfollows:
BrewGroupTemperature 203°F
SteamTankTemperature 250°F
BrewMode M(Manual)
Right‐HoldSaveLockout Locked
EnabledPrograms 1&2Enabled(3‐6Disabled)
TemperatureUnits Fahrenheit
Program1:Program2:
Pre‐Infusion 4seconds Pre‐Infusion 4seconds
RampUp 2seconds RampUp 2seconds
RampDown 92%RampDown 92%
TotalWaterCount 280TotalWaterCount 380