19
PROGRAMMING
ThisprogrammingseconappliestoallMVPSynesso™machines.MVPmachineshaveahandheld(wired)
controller,picturedbelow,toallowtheusertocomfortablyviewandchangethemachinesengs.
To change sengs on these screens, first press the line buon on the le side of the display associated
with the seng you wish to change. The value will flash once selected. Press the up or down buons unl
the desired value is displayed. Press the line buon again to confirm the change. The value will stop flash‐
ing. Use this procedure to change any variables in the controller menus.
Thetoplineofeveryscreenindicatesthetle.Inthiscase,TemperatureOverview.
You can return to this screen at any me by pressing the home buon at the top right of the controller.
Themachinewillalsoreturntothisscreenautomacallyaerashortme.
Lines2,3,and4maycontaininformaonorsengs,manyofwhichcanbechangedbytheoperator.This
screenprovidesthe
currenttemperaturesforeachbrewgroupalongwiththesteamtank.Themostrecent
errorwillalsobeshowninthelowerrightcorner.Nosengscanbechangedonthisscreen.
Insomecircumstances,numerictemperatureswillnotbeshown.Ifatankisreading‘LOW’,thisindicates
that
tankisbelowthetemperatureprobe’seffecverangeofmeasurement(170F‐270F/76.6C‐132.2C).
Readingsabovetheeffecverangewillshowas‘HIGH’.
Theprogrammabletemperaturerangeforabrewgroupisfrom180F(82.2C)upto220F(104.4C).Thefacto‐
rysettemperatureis
203F(95C).Tochangebrewgroupsettemperatures,refertopage20.
Thesteamtankissetbythefactorytoadefaultsengof250F(121.1C).Tochangethistemperature,see
page21.
The[OK]ontherighthandsideofline4isindicangthattherehavebeennoerrorsdetectedbythecontrol
system.If,inplaceofthe[OK]youfindanerrorcode(EX:STLW01),refertotheErrorLogcodesonpage23.
Tocycletothenextdisplayscreen,pressthedownarrowbuon.(Youmaypresstheuparrowinstead
to
travelbacktothepreviousscreen.)