14
STARTUP
Start‐Up Instrucons
1.Tofillthemachine,connectthewaterlines,connectthedrainhoseandturnthewaterON.
2.SwitchtheredelectronicsOn/OffswitchtoON.Thisacvatesthemachine’swaterauto‐fillfeaturefor
thesteamtankandtheelectronics,butNOTtheheangelements.
3.Thewaterlevelsightglassforthesteamtankislocatedontherightsideofthemachine.Asthetankfills,
thewaterlevelwillriseinthesightglassandwillautomacallystopwhenthepresetlevelisreached.
4.Bleedthegroupheadsofair:
HoldeachbrewgrouphandleleunlthecorrespondingdisplayreadsM:shieachgroupheadhandle
lemomentarily,(seepicturesbelow)allowthegrouptorununlthereisasteadyflowofwater.Shi
eachgroupheadrighttoturnoff.
5.Waitunlthesteamtankhasstoppedfillingandthelevelinthesightglassreadsatleast½full.Turnthe
heangelementbreakertotheONor(1)posion.Alltheheang elements(brewandsteam)arenowac‐
vated.
6.Toadjustthepumppressure,acvatethepumpbyshiingthebrewgrouphandlemomentarilyletwo
mesonMVPandthreemesonMVPHydra.
7.Locateandreadthepumppressure/brewgaugelocatedtotherightoftherightmostgrouponMVPs
andtotherightofeachgrouponMVPHydras.
8.Setthepumppressureto9Bar:
Locatethepumpadjusngscrewontherightsideofthebrasspumphousing.
Loosenthelocknutandturnthescrewwithascrewdriver:
ClockwisetoINCREASEpressure
CounterclockwisetoDECREASEpressure
Oncethedesiredpressureisreached,reghtenthelocknut.
9.Pleaseallowatleast30minutesof“warmup”mebeforeusingyourSynesso™espressomachineto
brewshotsorsteammilk.Thesteamgauge(thelehandgauge)shouldreadaminimumof1.1Bar.
CenterPosion‐AtRest ShiLe‐StartorAdvanceShiRight‐Offor
HoldLe‐changesMtoMPtoVPSelectBrewProgram