9-11
Standard Specifications for JSMA-PHH (200V Class)
JSMA-P□□□□
Motor Mode Symbol Unit
HH30A HH44A HH55A HH75A
Drive Model
100A3 150A3 200A3 300A3
Rated Output P
R
KW
3.00 4.40 5.50 7.50
Rated Torque T
R
Nm
19.10 28.00 35.10 47.80
Max. Torque T
max
Nm
49.50 71.40 89.60 122.60
Rated Speed N
R
rpm
1500
Max. Speed N
max
rpm
3000
Rated Current I
R
A
23.00 33.20 42.10 58.00
Max. Armature
Current
I
max
A
59.80 86.30 109.50 151.00
Torque Constant K
T
Nm/A
0.83 0.84 0.83 0.82
Rotor Moment of
Inertia
J
M
Kgcm
2
39.99 53.02 63.52 93.94
Armature Resistor Ra
0.08 0.05 0.04 0.02
Armature Inductance La mH
1.48 0.89 0.68 0.43
Mechanical Time
Constant
Tm ms
0.70 0.62 0.56 0.51
Electrical Time
Constant
Te ms
18.75 16.54 17.46 18.00
Weight(Standard) W kgw
19.5 26.2 30.0 42.0
Insulation Grade
Class F (155)
Operating Ambient
Temp.
T
0 ~ 40
Operating Ambient
Humidity
RH %
<90
Storage Temp. T
-20 ~ 60
Storage Humidity RH %
<90
1( kgfcm)0.0980665(Nm) 1(gfcms
2
)0.980665(kgcm
2
)