Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO2EMBD application module.
Group
Bus
Syntax
BUS:B<x>:SPI:DATA:SIZe <NR1>
BUS:B<x>:SPI:DATA:SIZe?
Arguments
<NR1> specifies the number of bits per word.
Examples
BUS:B1:SPI:DATA:SIZe 16 sets the data size to 16.
BUS:B1:SPI:DATA:SIZe? might return BUS:B1:SPI:DATA:SIZe 8
indicating that the data size is 8 bits.
BUS:B<x>:SPI:FRAMING
Sets or returns the type of SPI framing.
Conditions
This command requires a DPO2EMBD application module.
Group
Bus
Syntax
BUS:B<x>:SPI:FRAMING {SS|IDLEtime}
BUS:B<x>:SPI:FRAMING?
Arguments
SS specifies framing by SS (non 2-wire).
IDLEtime specifies framing by Idle Time (2-wire).
Examples
BUS:B1:SPI:FRAMING SS sets the SPI framing type to SS.
BUS:B1:SPI:FRAMING IDLETIME might return BUS:B1:SPI:FRAMING
IDLETIME
indicating that the SPI framing type is set to IDLETIME.
BUS:B<x>:SPI:IDLETime
Sets or returns the SPI bus idle time in seconds for the specified SPI bus.
Conditions
This command requires a DPO2EMBD application module.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-89