Commands Listed in Alphabetical Order
Syntax
BUS:B<x>:CAN:
PRObe {CA NH|CANL|RX|TX|DI FFerential}
BUS:B<x>:CAN:PRObe?
Arguments
CANH specifies the single-ended CANH signal, as specified by the CAN standard.
CANL specifies the single-ended CANL signal, as specified by the CAN standard.
RX specifies the receive signal on the bus side of the CAN transceiver.
TX specifies the transmit signal.
DIFFerential specifies the differential CAN signal.
BUS:B<x>:CAN:SAMPLEpoint
Sets or returns the sampling point during each bit period for bus <x>, where x
is the bus number
Conditions
This command requires a DPO2AUTO application m odule.
Group
Bus
Syntax
BUS:B<x>:CAN:SAMPLEpoint <NR1>
BUS:B<x>:CAN:SAMPLEpoint?
Arguments
<NR1> is the sample point in percent. Values are limited to 25, 30, ... 70, 75.
BUS:B<x>:CAN:SOUrce
Sets or returns the CAN bus data source for bus <x>, where x is the bus number.
Conditions
This command requires a DPO2AUTO application m odule.
Group
Bus
Syntax
BUS:B<x>:CAN:SOUrce {CH1|CH2|CH3|CH 4|
D0|D1|D2|D3|D4|D5|D6|D7|D 8|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:CAN:SOUrce?
2-74 MSO2000B, DPO2000B, MSO2000 and DPO2000 Series O scilloscopes Programmer Manual