Commands Listed in Alphabetical Order
Group
Power
Syntax
POWer:GATESOurce {CH1|CH2|CH3|CH4|REF1|REF2|REF 3|REF4|NONe}
POWer:GATESOurce?
Arguments
CH1–CH4 sets an analog channel as the gate source.
REF1–REF4 sets a reference waveform as the gate source.
NONe is set when the gate source is not used in the application.
Examples
POWER:GATESOURCE CH1 sets the gated source as CH1.
POWER:GATESOURCE? might return POWER:GATESOURCE CH2 indicating that
CH2 is the gated source.
POWer:GATing
This command specifies the power application gating.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:GATing {OFF|SCREen|CURSor}
POWer:GATing?
Arguments
OFF turns off measurement gating (full record).
SCREen turns on gating, using the left and right edges of the screen.
CURSor limits measurements to the portion of the waveform between the vertical
bar cursors, even if they are off screen.
Examples
POWER:GATING CURSOr sets cursor gating on the oscilloscope.
POWER:GATING? might return POWER:GAT ING OFF indicating that gating is
turned off on the oscilloscope.
2-466 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual