Commands Listed in Alphabetical Order
Related Commands
RF:MEASUre:CP
:POWer?
Arguments
<NR3> is a floating point number.
Examples
RF:MEASUre:CP:CHANBW 5.0000E+6 sets the channel width to 5 MHz.
RF:MEASUre:CP:POWer? (Query Only)
This query returns the total channel power
within the displayed channel
bandwidth, when the RF measurement type has been set to CP (using the
command RF:MEASUre:TYPe).
Group
RF
Syntax
RF:MEASUre:CP:POWer?
Related Commands
RF:MEASUre:CP:CHANBW
Examples
RF:MEASure:CP:POWer? might return 5.23 in whatever units have been selected
using
RF:UNIts.
RF:MEASUre:OBW:CHANBW
This command specifies the Analysis Bandwidth to use, when the RF measurement
type has been set to OBW (using the command RF:MEASUre:TYPe). Note that
the span automatically increases or decreases to be 10% more than the Analysis
Bandwidth (providing some room around the signal of interest).
Conditions
MDO3000, MDO4000/B, or MDO4000C models with option SA3 or SA6 only.
Group
RF
Syntax
RF:MEASUre:OBW:CHANBW <NR3>
RF:MEASUre:OBW:CHANBW?
Related Commands
RF:MEASUre:OBW:POWer?, RF:MEASUre:OBW:PERCENTdown,
RF:MEASUre:OBW:LOWERFreq?, RF:MEASUre:OBW:UPPERFreq?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-559