EasyManuals Logo
Home>Tektronix>Test Equipment>MDO3104

Tektronix MDO3104 User Manual

Tektronix MDO3104
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
Trigger Setup
Checking Trigger Settings
To quickly det
ermine the settings of some
key trigger parameters, check the Trigger
readout at the bottom of the display. The
readouts d iff
er for edge and the advanced
triggers.
1. Trigger source = channel 1.
2. Trigger slope = rising.
3. Trigger level = 0.00 V.
Edge trigger readout
Using Sequence Trigger (A (Main) and B (Delayed))
Combine an edge A Event (Main) trigger with the B Event (Delayed) trigger to capture m ore complex signals. After the A
Event occurs, the trigger system looks for the B Event before triggering and displaying the waveform.
A and B triggers can (and typically do) have separate sources.
NOTE. You can select sequence triggering when you choose the slope type Falling or Rising but not when you pick
the slope type Both.
Use the Edge trigger menu to set up the A trigger rst. Then, to use the B trigger:
1. P ush Trigger Menu.
2. Push Type.
3. Turn Multipurpose a to select a trigger type
of Sequence (B Trigger).
This brings up the Sequence (B Trigger)
menu.
4. Push BTriggerAfterA.
Type
Sequence
(B Trigger)
Source
1
Coupling
DC
Slope
Level
0.00 V
B Trigger
After A
Time
Mode
Auto
& Holdoff
100 MDO3000 Series Oscilloscopes User Manual

Table of Contents

Other manuals for Tektronix MDO3104

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO3104 and is the answer not in the manual?

Tektronix MDO3104 Specifications

General IconGeneral
BrandTektronix
ModelMDO3104
CategoryTest Equipment
LanguageEnglish

Related product manuals