Acquire the Sign
al
Setting Up Digital Channels (MSO2000B Series Only)
Use front-panel buttons and knobs to set up your oscilloscope to acquire signals using the digital channels available
only on MSO 2000B models.
1. Connect the P6316 digital probe to the input
signal source.
2. Connect the ground lead or leads to the
circuit ground.
You can connect one or two of the common
ground leads for each group of 8 channels
(wires).
3. If needed, connect the appropriate grabber
for each channel to the p robe tip.
4. Connect each channel to the desired circuit
test point.
5. Push the D15 - D0 front panel button to
display the menu.
6. Push the lower-bezel D15 - D0 button to
access the D15 - D0 On or Off menu.
D15–D0
On/Off
Thresholds Edit Labels Height
S |ML
MSO2000B and DPO2000B Series Oscilloscopes User Manual 59