EasyManuals Logo
Home>Tohnichi>Tools>ProTork CPT20X10D-G

Tohnichi ProTork CPT20X10D-G User Manual

Tohnichi ProTork CPT20X10D-G
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
00
0.0
N・m
--
MODE_S
--
PARA_S
Ar
0.0
Ar
0.5
18
Select
Before Setting
After Setting
Other settings
Use ▲▼ key to set the memory counter to 00 (RUN
measuring mode).
Keep MD key pressed for more than 2 seconds till it
the display changes.
●Selecting setting subject 
Select MODE_S setting on tightening mode and
torque setting), or PARA_S (other parameter settings.
Use ▲▼ key to select PARA_S and press MEM key to
save and proceed to the next.
(Press MD key to proceed without saving. Press C key
to return to RUN measuring mode).
●Setting measurement unit (Default: N
m)
Select the torque unit
N
m kgf
cm kgf
m lbf
in lbf
ft
The measured torque and the set torque will be
converted into the selected torque unit.
Use ▲▼key to select the torque unit and press MEM
key to save and proceed to the next.
(If you press MD key, it proceeds without saving. If you
press C key, it returns to RUN measurement mode).
●Setting Auto memory/Reset timer (Default: 0.0)
Set Auto memory/Reset t imer. After ti ghtening
completion, the auto memory function saves the data
automatically after the set timing, and proceed to the
next counter.(0.1 - 5 seconds
If you set it to "00", then Auto memory/Reset function
will be ineffective.
Use ▲▼ key to select the timing (second) and press
MEM key to save and proceed to the next.
(Press MD key to proceed without saving. Press C key
to return to RUN measuring mode.)
UNIT
USEL
N・m
Select the torque unit
N
m kgf
cm kgf
m lbf
in lbf
ft
Unit conversion table
Conversion factores
N
m
kgf
cm 10.1972
N
m
kgf
m 0.101972
N
m
lbf
in 8.8508
N
m
lbf
ft 0.73756
Rounding of the converted gures
100.0[N
m] × 0.73756 73.756 73.8[lbf
ft]
73.8[lbf
ft] ÷ 0.73756 100.05 100.1[N
m]
Converted gures are rounded as above.
Accordingly, the resulted gures may have a margin of errors.
Unit conversion is made based on N.m values with the above conversion factors.
All the memory and torque setting values are converted when making a unit change.