Error message will appear in malfunction of Auto Zero function activated by C key. In addition, the key check function will
be activated when POWER is turned on at OFF condition, or when Reset switch is used.
・ Err1 :
・ Err 2 :
・ Err 3 :
・ Err 4 :
・ Err 5 :
・ Err 8 :
・ Err 9 :
《In case of Err 1-5》
Error of the membrane switch
◎ Turn off the power once and turn it on without touching any other keys.
・ If Err disappears, it should work properly.
・ If Error does not disappear, it needs to be repaired. Please contact TOHNICHI MFG.CO.,LTD. or your nearest
distributor.
《In case of Err 8》
・ Malfunction of data memory.
・ It needs to be repaired. Please contact TOHNICHI MFG.CO.,LTD. or your nearest distributors.
《In case of Err 9》
Malfunction of the torque sensor or circuit board.
◎ Push Clear key at no loading condition.
・ If Err 9 disappears, it should work properly.
If Err 9 remains, it needs to be repaired. Please contact TOHNICHI MFG.CO.,LTD. or your nearest distributors.
21
11. Error Message
Appears if Power is turned on or Reset Switch is pushed while ▲ key is being ushed.
Appears if Power is turned on or Reset Switch is pushed while ▼ key is being pushed.
Appears if Power is turned on or Reset Switch is pushed while MEM key is being pushed.
Appears if Power is turned on or Reset Switch is pushed while C key is being pushed.
Appears if Power is turned on or Reset Switch is pushed while MD key is being pushed.
Malfunction of data memory.
Malfunction of the torque sensor or circuit board.