Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78
Digit 1, 2, 3, 4 – Unit Model
RTSF
Digit 5, 6, 7 – Unit size
50 = 50 Nominal tons
60 = 60 Nominal tons
70 = 70 Nominal tons
90 = 90 Nominal tons
100 = 100 Nominal tons
110 = 110 Nominal tons
Digit 8 – Unit Power supply
D = 400 V – 50 Hz – 3Ph
Digit 9 – Factory
E = Europe
F = ICS
Digit 10 & 11 – Design sequence
(Factory assigned)
Digit 12 & 13 – Not used
Digit 14 – Agency listing
C = CE marking
Digit 15 – Pressure Vessel Code
2 = PED (Pressure Equipment Directive)
Digit 16 – Unit Application
X = Cooling Mode - Below 50°C Leaving Condenser Temp
H = Cooling Mode - Above 50°C Leaving Condenser Temp
L = Heat pump - Below 50°C Leaving Condenser Temp
M = Heat pump - Above 50°C Leaving Condenser Temp
Digit 17 – Refrigerant
Z = R1234ze unit with Factory charge (with oil)
Y = R1234ze with pre-charge (with oil)
L = R1234ze unit with Nitrogen (no oil)
Digit 18 – Sound Attenuation Package
X = Without
A = Aesthetic option
L = Sound attenuation package
Digit 19 – Relief Valve Option
L = Single Relief Valve Condenser
2 = Single Relief Valve Condenser & Evaporator
D = Dual relief valve with 3 way valve condenser
4 = Dual relief valve with 3 way valve condenser & Evaporator
Digit 20 – Compressor Type
L = CHHP Low VI
H = CHHP or CHHW High VI
Digit 21 – Evaporator Size
A = Evaporator A
B = Evaporator B
C = Evaporator C
D = Evaporator D
Digit 22 & 23 & 24 – Not Used
Digit 25 – Evaporator Water side Pressure
X = 10 Bar Evaporator Water Pressure
Digit 26 – Evaporator application
N = Comfort Cooling (above 5°C)
P = Process Cooling below 5°C
C = Ice Making (from -7°C to 20°C)
Digit 27 – Not Used
Digit 28 – Evaporator pump
X = Without
Digit 29 – Condenser Size
A = Condenser A
B = Condenser B
C = Condenser C
D = Condenser D
Digit 30 & 31 – Not Used
Digit 32 – Condenser Pump
X = Without
Digit 33 – Condenser Water side pressure
X = 10 Bar Condenser Water Pressure
Digit 34 – Condenser Thermal Insulation
X = Without
H = With Condenser Insulation
Digit 35 – Oil cooler
X = Without
C = With
Digit 36 – Evaporator Pump Smart Flow control
X = Without
E = VPF Constant Delta T Evaporator
Digit 37 – Power Protection
F = Disconnect switch with fuses
B = Disconnect switch with circuit breakers
Digit 38 – Not Used
Digit 39 – Relay Card
1 = With additional relay card
Digit 40 – Smart com protocol
X = Without
B = BACnet MSTP interface
C = BACnet IP interface
M = Modbus RTU interface
L = LonTalk interface
Digit 41 – Communication customer input/output
X = Without
A = External Set points & Capacity outputs – Voltage Signal
B = External Set points & Capacity outputs – Current Signal
Digit 42 – Outdoor Air Temperature Sensor
X = Without
A = Outdoor Air Temperature Sensor – CWR/Low Ambient
Digit 43 – Not Used
Digit 44 – Master Slave Set
X = Without
M = With
Unit model number description

Other manuals for Trane CITY RTSF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane CITY RTSF Series and is the answer not in the manual?

Trane CITY RTSF Series Specifications

General IconGeneral
BrandTrane
ModelCITY RTSF Series
CategoryChiller
LanguageEnglish

Related product manuals