WSHP-SVX01Y-EN
Model Number Description
Digits 1–3 — Unit Configuration
GEH = Standard Efficiency Horizontal 0.5 to
15 Tons
GEV = Standard Efficiency Vertical 6 to 25
Tons
Digit 4 — Development Sequence
E = R-410A
Digits 5–7 — Nominal Capacity
006 = 0.5 Tons
009 = 0.75 Tons
012 = 1 Tons
015 = 1.25 Tons
018 = 1.5 Tons
024 = 2 Tons
030 = 2.5 Tons
035 = 3 Tons
042 = 3.5 Tons
048 = 4 Tons
060 = 5 Tons
072 = 6 Tons
090 = 7.5 Tons
120 = 10 Tons
150 = 12.5 Tons
180 = 15 Tons
240 = 20 Tons
300 = 25 Tons
Digit 8 — Voltage (Volts/Hz/Phase)
0 = 115/60/1
1
1 = 208/60/1
2 = 230/60/1
3 = 208/60/3
4 = 460/60/3
5 = 575/60/3
6 = 220–240/50/1
7 = 265/60/1
8 = 230/60/3
9 = 380–415/50/3
Digit 9 — Heat Exchanger
1 = Copper-Water Coil
2 = Cupro-Nickel Water Coil
7 = Insulated Copper-Water Coil
8 = Insulated Cupro-Nickel Water Coil
Digit 10 — Current Design Sequence
Digit 11 — Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit with Hot Gas
Reheat
3 = Heating and Cooling Circuit with
Waterside Economizer
4 = Heating and Cooling Circuit with HGR and
WSE
2
Digit 12 — Blower Configuration
1 = Standard Blower Motor
3
2 = High Static Blower Motor
3
A = Drive Package A
B = Drive Package B
C = Drive Package C
D = Drive Package D
E = Drive Package E
F = Drive Package F
G = Drive Package G
H = Drive Package H
J = Drive Package J
1* = 2 Speed Drive Package A
2* = 2 Speed Drive Package B
3 = 2 Speed Drive Package C
4 = 2 Speed Drive Package D
5 = 2 Speed Drive Package E
6 = 2 Speed Drive Package F
7 = 2 Speed Drive Package G
8 = 2 Speed Drive Package H
9 = 2 Speed Drive Package J
Digit 13 — Freeze Protection
A = 20°F Freezestat
4
B = 35°F Freezestat
Digit 14 — Open Digit = 0
Digit 15 — Supply-Air Arrangement
B = Back Supply-Air Arrangement
F = Front Supply-Air Arrangement
L = Left Supply-Air Arrangement
R = Right Supply-Air Arrangement
T = Top Supply-Air Arrangement
5
Digit 16 — Return-Air Arrangement
B = Back Return-Air Arrangement
2
F = Front Return-Air Arrangement
2
L = Left Return-Air Arrangement
R = Right Return-Air Arrangement
Digit 17 — Control Types
D = Deluxe 24V Controls
B = Tracer® ZN524 Controls
F = UC400
G = UC400 w/Wireless Comm
Digit 18 — Tstat/Sensor Location
0 = Wall Mounted Location
Digit 19 — Fault Sensors
1 = Condensate Overflow Sensor
3 = Condensate Overflow and Filter
Maintenance Timer
6 = Condensate Overflow and Fan Status
J = Fan Status, Filter Maintenance Timer and
Condensate Overflow Sensor
Digit 20 — Temperature Sensor
0 = No Temperature Sensor
1 = Entering Water Sensor
Digit 21 — Insulation
1 = Standard Fiberglass Insulation
2 = Foil-faced Insulation in Airstream
3
Digit 22 — Electric Heat
0 = No Electric Heat
1 = Internal Boilerless Electric Heat
3
4 = External Boilerless Electric Heat
5 = External Supplemental Electric Heat
2
Digit 23 — ON/OFF Switch
0 = No “ON”/“OFF” Switch
1 = “ON”/“OFF” Switch
6
Digit 24 — Filter Type
1 = 1" Throwaway Filter
2 = 2" Throwaway Filter
4 = 2” MERV 8
5 = 2” MERV 13
Digit 25 — Acoustic Arrangement
0 = Enhanced Sound Attenuation
1 = Deluxe Sound Attenuation
7
Digits 26–36 — Does Not Apply to GEH
or GEV
00000000000 = Digits 26-36 are not
applicable to the GEH or GEV products
Digits 35 — Unit Drain Pan Option
A = Polymer Drain Pan
B = Stainless Steel Drain Pan
Model Number Notes
Notes:
1. 0.5 to 1 Ton only
2. 6 to 25 Tons only
3. 0.5 to 5 Tons only
4. Extended Range Geothermal
5. Only available on vertical units
6. ON/OFF switch not available with
boilerless electric heat option or units
over 60 amps
7. 0.5 to 5 Tons (horizontal only)