WSHP-SVX01Y-EN
7
GEV Models
Digits 1–3 Unit Configuration
GEV = Standard Efficiency Vertical
Digit 4 Development Sequence
G
Digits 5–7 Nominal Size (MBH)
006 = 6.0 MBH
009 = 9.0 MBH
012 = 12.0 MBH
015 = 15.0 MBH
018 = 18.0 MBH
024 = 24.0 MBH
030 = 30.0 MBH
036 = 36.0 MBH
042 = 42.0 MBH
048 = 48.0 MBH
060 = 60.0 MBH
Digit 8 Voltage (Volts/Hz/Phase)
4 = 460/60/3
7 = 265/60/1
A = 208-230/60/1
B = 208-230/60/3
Digit 9 Heat Exchanger
1 = Copper-Water Coil
2 = Cupro-Nickel Water Coil
7 = Insulated Copper-Water Coil/Suction Line
8 = Insulated Cupro-Nickel Water Coil/
Suction Line
Digit 10 Design Sequence
A First Design Sequence
Digit 11 Refrigeration Circuit
0 = Heating and Cooling Circuit
2 = Heating and Cooling Circuit with Hot Gas
Reheat
3 = Heating and Cooling Circuit with
Waterside Economizer
4 = Heating and Cooling Circuit with
Waterside Economizer, Hot Gas Reheat
Digit 12 Blower Configuration
K = Variable ECM Motor, Constant Torque
Digit 13 Freeze Protection
A = 20°F Freezestat
B = 35°F Freezestat
Digit 14 Open Digit = 0
Digit 15 Supply-Air Arrangement
T = Top Supply-Air Arrangement
B = Back Supply-Air Arrangement
Digit 16 Return-Air Arrangement
L = Left Return-Air Arrangement
R = Right Return-Air Arrangement
Digit 17 Control Types
B = Tracer® ZN524 Controls
D = Deluxe 24V Controls
H = UC400/B
J = UC400B w/Air-Fi® Wireless
Communications
Digit 18 Tstat/Sensor Location
0 = Wall Mounted Location
Digit 19 Fault Sensors
1 = Condensate Overflow Sensor
3 = Condensate Overflow and Filter
Maintenance Timer
6 = Condensate Overflow and Fan Status
J = Fan Status, Filter Maintenance Timer and
Condensate Overflow Sensor
Digit 20 Temperature Sensor
0 = No Additional Temperature Sensor
1 = Entering Water Sensor
Digit 21 Insulation
1 = Matte Faced Insulation
2 = Foil Faced Insulation
Digit 22 Electric Heat Option
0 = No Electric Heat
6 = Factory Mounted External Boilerless Low
Electric Heat
7 = Factory Mounted External Supplemental
Low Electric Heat
8 = Field Mounted External Boilerless Electric
Heat
9 = Field Mounted Supplemental Electric Heat
A = Factory Mounted External Boilerless
Medium Electric Heat
B = Factory Mounted External Supplemental
Medium Electric Heat
C = Factory Mounted External Boilerless High
Electric Heat
D = Factory Mounted External Supplemental
High Electric Heat
Digit 23 Unit Mounted Disconnect
0 = No Unit Mounted Disconnect
2 = Unit Mounted Disconnect
Digit 24 Filter Type
1 = 1-inch Throwaway Filter
2 = 2-inch Throwaway Filter
4 = 2-inch MERV 8
5 = 2-inch MERV 13
Digit 25 Acoustic Arrangement
1 = Standard Sound Attenuation
2 = Deluxe Sound Attenuation
Digits 26–36 Does Not Apply
00000000000 = Digits 26-36 are not
applicable to the GEH or GEV products
Digit 37 Ducted Filter Rack
0 = Non-ducted filter rack
A = Ducted Filter Rack (Side Access/LH—RH)
Digit 38 Isolation Valve
0 = No Isolation Valve
1 = Factory Mounted Isolation Valve
Digit 39 Power Connection
1 = Single Point
2 = Dual Point (Electric Heat Power Separate
from Unit)
Digit 40 Drain Pan
A = Polymer Drain Pan
B = Stainless Steel Drain Pan
Model Number Note:
Note: Back Supply, Electric Heat and Deluxe
Sound option are avalible in later
product release.
MMooddeell NNuummbbeerr DDeessccrriippttiioonn