30 BAS-SVX44A-EN
Functions
2. Next, touch in the fan selection box to put the thermostat into TOV Temporary Override
Mode and to step to the next available setting as shown below.
3. Refer to the next section, Temporary
Override (TOV) Setup to set overrides or touch to
cancel and return to the Home screen.
Temporary Override (TOV) Setup
TOV allows the user to temporarily override the scheduled temperature setpoint and/or fan
settings. There are two ways to enter TOV Mode from the Home screen:
Quick
TOV: Touch the Occ ( ) or Unocc ( ) icon from the Home screen. A TOV session will
start up using the last occupied schedule setpoint settings, the last occupied fan setting, and the
default
TOV time period (Option Number 0230). Touch OK or wait for a 20-second time out to
put the thermostat into quick TOV Active Mode; OR
User
Configurable TOV: Touch either the Up or Down arrow to blink the setpoint for 20 seconds.
Touch of the Up or Down arrows within 20 seconds to change the setpoint and put the
thermostat into TOV Setpoint Change Mode; OR
Touch the Fan to blink the present Fan setting for 20 seconds. Touch the Fan area within 20
seconds
to change the Fan setting and put the thermostat into TOV Setpoint Change Mode.
In TOV
Setpoint Change Mode, further adjustments can be made to the setpoint or Fan mode
with the Up, Down, or Fan areas.
Note: For
Auto H/C systems, use the cool mode icon ( ) or the heat mode icon ( ) to toggle
between cool and heat setpoints respectively.
To adjust the TOV time period:
Touch
the clock icon ( ) to enter TOV Time Setup Mode. The left/right arrow ( or )
will toggle between Days/Hours and the middle Up/Down arrows ( or ) will
increment or decrement the time.
Note: A
second touch of the clock icon ( ) will put the thermostat into Hold Mode
which holds the TOV settings indefinitely until canceled by the user. Additional
touches
of the clock icon ( ) will toggle the thermostat between DAYS/HOURS
and Hold.
Toggle
back to readjust the setpoint(s) by touching the thermometer icon ( ).
Touch area to activate the desired settings. Active TOV is indicated by a solid non-blinking
hourglass ( ).
Note: Desired
settings are also activated after a 20-second time out.
•ToCancel the
TOV time period, touch at any time to cancel and exit TOV Mode.
General Notes:
TOV setup has three modes: TOV Setpoint Setup, TOV Time Setup, and TOV Active.
If Fan is enabled, then TOV Fan setting can be changed in either TOV
Setpoint Mode or TOV
Time Setting Mode.
If a TOV is in active status, then those TOV settings become the starting setpoints if entering into
a
new User Configurable TOV session.
Fan icons do not display on the LCD screen if the system is not configured for fans.
The confirm icon is not displayed when the user is in TOV
Active Mode.
On Mode:
Arrows Flash
Auto Mode:
Auto Flashes
B C E
F
G

Table of Contents

Other manuals for Trane THT02775

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane THT02775 and is the answer not in the manual?

Trane THT02775 Specifications

General IconGeneral
BrandTrane
ModelTHT02775
CategoryThermostat
LanguageEnglish

Related product manuals