70
7.3 Interface
Interface menu allows users to configure the printer’s I/O interfaces.
7.3.1 Serial
The table below describes the configurable items for the printer’s RS-232 interface.
Item
Description
Default
Baud Rate
Sets Baud Rate for the RS-232 interface. Setting options: 1200 / 2400 / 4800 / 9600 / 19200 / 38400 /
57600 / 115200 bps.
9600
Parity
Sets parity check for the RS-232 interface. Setting options: None / Even / Odd.
None
Data Bits
Sets the number of bits in a data frame for the RS-232 interface. Setting options: 7 / 8.
8
Stop Bit
Sets the number of stop bits that mark the end of a frame for the RS-232 interface. Setting options: 1 / 2.
1
Interface
Serial
Ethernet
Wi-Fi
Bluetooth