ISSUE RESOLUTION
F1: Blower Running
Status Bad
1. Verify motor spins freely.
o
Motor seized:
Unplug oven and correct obstruction or replace motor.
o
Motor spins freely: Verify motor windings (see table below).
2. Verify motor windings are OK. Measure the resistance between
windings and chassis. Unplug oven and replace motor if resistances do
not agree with the values in the table below. If motor is OK, proceed to
step 3, below.
3. Determine if status indicator “A” is highlighted/backlit in TEST MODE.
o
“A” is highlighted/backlit.
a. Disconnect control wiring.
b. Ground OR-9 to chassis to remove backlight on “A”.
c. Keeping OR-9 grounded, check terminals on the control wiring
plug for 0-10 VDC control voltage (reference drawing of QC3
plug on schematics (pages 55-63) while incrementing blower
speed in TEST MODE (see BLOWER SPEED, page 15).
d. If DC voltage is present throughout all speed settings in TEST
MODE (see BLOWER SPEED, page 15), replace motor controller. If
not, check harness and/or replace I/O board.
MOTOR WINDING RESISTANCES TABLE
TO FROM
DESCRIPTION EXPECTED RESISTANCE
Black Red Winding (A-B) 2.0 – 2.6 Ohms
Black White Winding (A-C) 2.0 – 2.6 Ohms
Red White Winding (B-C) 2.0 – 2.6 Ohms
Black, White
or Red
Green Windings to Chassis Open
THE CONVECTION CIRCUIT
50

Table of Contents

Other manuals for TurboChef TORNADO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TurboChef TORNADO and is the answer not in the manual?

TurboChef TORNADO Specifications

General IconGeneral
BrandTurboChef
ModelTORNADO
CategoryOven
LanguageEnglish

Related product manuals