18 Keyboard Manual
Magnetic Reader, continued
Track 2 Account Number Only
If only track 2 is enabled (see previous page), only the account
number from track 2 and the start/stop sentinels are output.
If tracks other than track 2 are enabled, this parameter actually
outputs all the other track’s data, the account number from track 2,
and their start/stop sentinels.
Default is “No”.
Separator Character
Insert one character between each track’s output.
Pre-defined characters include:
The above special characters must be bracketed by < > symbols as
shown.
Function codes (F keys, Cursor up, Enter, etc.) can also be inserted
via hexadecimal code (accessable in a linked menu) and must
include surrounding brackets (<>).
Letters and numbers should be entered directly by keyboard input
without surrounding brackets (<>).
Default is “None”.
<t>: Tab
•
•
<n>: Line Feed
•
<d>: Any Digit (not applicable to this function)
•
<a>: Any Letter (not applicable to this function)
•
<*>: Interblock Delay (not applicable to this function)
•
<“>: “ (quotation marks)
•
<dd>: character in hexadecimal notation
•
<<>: <
•
<>>: >
Output Only When All Tracks Have Correct Data
A useful function for insuring data integrity, this function can cause
trouble when the card reader tries to read more tracks than are on the
card.
Default is “No”.