24 Keyboard Manual
Bar Code Symbologies, continued
UPC-A
Send Check Digit toggles whether or not to send a check digit.
Default is “Send”.
Send Leading Digit toggles sending or not sending a leading
(“start bar code”) digit. Default is “Send”.
Code ID is a user-definable identification letter for UPC-A, which
is referred to in the “Use Code ID” function (see page 11).
Default is letter “A”.
Enabled toggles the ability for the keyboard/scanner to read
UPC-A on or off. Default is “Yes”.
Codabar
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “48”.
Minimum Length defines the minimum length the user will
accept for a valid bar code. Default is “3”.
CLSI Format deletes the start and stop sentinels and outputs the
data with spaces inserted after the 1st, 5th, and 10th characters.
Default is “No”.
Check Digit defines whether or not a check digit (to insure data
accuracy) is calculated, and if so, whether it should be sent or
not. Default is “Not Calculate”.
Send Start/Stop toggles sending or not sending start/stop
sentinels. Default is “No Send”.
Code ID is a user-definable identification letter for Codabar,
which is referred to in the “Use Code ID” function (see page 11).
Default is letter “N”.
Enabled toggles the ability for the keyboard/scanner to read
Codabar on or off. Default is “No”.

Table of Contents

Other manuals for Unitech KP3800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Unitech KP3800 and is the answer not in the manual?

Unitech KP3800 Specifications

General IconGeneral
BrandUnitech
ModelKP3800
CategoryKeyboard
LanguageEnglish

Related product manuals