S
CANNER
O
PERATION
Miscellaneous Decode Features
³118113
* Optional Same Symbol Check - Requires 1
different character between successive bar codes
to consider the bar code “new”.
³118103
Normal Same Symbol Check - Requires 3
different characters between successive bar codes
to consider the bar code “new”.
Same Symbol Time Outs
The length of time before a bar code can be rescanned after it is removed from
the scan field is user-configurable in increments of 50 msecs to 6350 msecs
(6.35 sec).
³918900
~ Variable Same Symbol Time Out - In configuration
mode, scan this bar code followed by the appropriate
code byte sequence to set the same symbol time out
duration.
³818900
No Same Symbol Time Out
³118917
Infinite Same Symbol Time Out - The scanner will
not repetitively scan the same bar code. This
option overrides the symbol rescan time-outs.
LED Options
³118313
Flash Green LED if Rescan Allowed - This
indicates same symbol timeout has elapsed.
³118303
* Do Not Flash Green LED if Rescan Allowed
³118312
Reverse LED Functions - Red = Laser On
Green = Good Read
³118302
* Normal LED Functions - Green = Laser On
Red = Good Read
5