7. Water outlet
- In the envelope that is placed
inside the box you can find a 90°
bend that can be connected to the
drain pipe. and should then be
connected using a rigid pipe or
flexible hose.
- The use of a siphon is
recommended in the connection to
the grey water circuit, in order to
prevent the steam release from the
exhaust.
- In compliance with law regulations
it could be mandatory to separate
the drain pipe to the grey water
circuit. This could help the clean
operations in the back of oven.
- On all ChefTop ovens a solenoid
valve is mounted on the exhaust
pipe inside the oven for cooling the
output liquids. The solenoid valve
works always are used the steam
(STEAM.Maxi) during cooking in the
oven. This valve has a flow rate of 18
L/h.
29
90° bend
Water outlet
Water outlet system connections
min 4°
min 4°
25 mm
min 4°
25 mm
Solenoid valve
for cooling
output liquids