55
English
MANTIS USER MANUAL
8. GLOSSARY
AVG: Average depth, calculated from the beginning of the dive or from the time of reset.
CCR: Closed Circuit Rebreather.
CNS O
2
: Central Nervous System oxygen toxicity.
DESAT: Desaturation time. The time needed for the body to completely eliminate any
nitrogen taken up during diving.
Dive time: The time spent below a depth of 0.8m/3ft.
Gas: Refers to the main gas that is set for the ZH-L8 ADT MB algorithm.
Local time: The time in the local time zone.
Max depth: Maximum depth reached during the dive.
MB: Microbubble. Microbubbles are tiny bubbles that can build up in a diver’s body
during and after a dive.
MB level: One of the six steps, or levels, in SCUBAPRO’s customizable algorithm.
MOD: Maximum Operating Depth. This is the depth at which the partial pressure of
oxygen (ppO
2
) reaches the maximum allowed level (ppO
2
max). Diving deeper than
the MOD will expose the diver to unsafe ppO
2
levels.
Multi gas: Refers to a dive in which more than one breathing gas is used (air and/or Nitrox).
Nitrox: A breathing mix made of oxygen and nitrogen, with the oxygen concentration
being 22% or higher. In this manual, air is considered as a particular type of
Nitrox.
NO FLY: Minimum amount of time the diver should wait before taking a plane.
No-stop time: This is the time that a diver can stay at the current depth and still make a direct
ascent to the surface without having to perform decompression stops.
O
2
: Oxygen.
%O
2
: Oxygen concentration used by the dive computer in all calculations.
PDIS: Profile Dependent Intermediate Stop is an additional deep stop which is
suggested by MANTIS at depth where 3rd or 4th compartment starts off gassing.
ppO
2
: Partial pressure of oxygen. This is the pressure of the oxygen in the breathing
mix. It is a function of depth and oxygen concentration. A ppO
2
higher than
1.6bar is considered dangerous.
ppO
2
max: The maximum allowed value for ppO
2
. Together with the oxygen concentration it
defines the MOD.
Press: The act of pressing and releasing one of the buttons.
Press and hold: The act of pressing and holding one of the buttons for 1 second before releasing it.
INT.: Surface interval. Elapsed time since your last dive has ended.
SOS mode: The result of having completed a dive without respecting all mandatory
decompression obligations.
Stopwatch: A stopwatch. To time certain steps of the dive.
UTC: Universal Time Coordinated, refers to time zone changes when traveling.