Ratings
Model NP
Gas Natural Propane
Altitude (Ft.)* 0-4,500 feet*
Input Maximum (Btu/h) 36,000 34,000
Input Minimum (Btu/h) 19,000 21,000
Manifold Pressure (in
w.c.)
4” 10”
Minimum Supply
Pressure (in w.c.)
5” 11”
Maximum Supply
Pressure (in w.c.)
10” 14”
Main Burner Injector
Marking
1000 380
Pilot Injector Marking 51 30
Min. Rate By-Pass
Screw
220 160
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
Specifi cations
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1700IN is used with natural gas.
Heater engine 1700IP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section above.
The supply connection is 3/8” NPT male and located
on the left hand side of the fi rebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
unit during service. See Supply Gas Installation section
for details.
Conversion Kits
The 1700 L2 is supplied as natural gas or propane gas
and is fi eld convertible between fuels. See instructions
packaged with the conversion kit for further information.
Electrical
The 1700 is designed to run on battery power and
does not require an electrical power source to operate
as a heater. However, it requires electrical power to
operate optional 1565LLK Linear Lighting Kit, 1595CFK
Circulating Fan Kit or 1270RBK Remote Blower Kit.