Installation - Accessories
Seismic Detectors Application Guide
GMSW7 SensTool software is an essential part of configuration, commissioning, diagnos-
tics, and fault finding for the GM730, GM760 & GM775 detectors.
A laptop with a serial port or a serial to USB conversion interface will be required to use this pro-
gram.
4.10 GMXC2 conduit connection cover
Figure 4-20: GMXC2 conduit connection cover
The GMXC2 is a plastic shroud, which provides a professional method of connecting cable conduit
to a seismic detector. The cable access apron of the detector needs to have sections removed to
enable the GMXC2 to slide into the apron.
Conduit external diameter = 16mm, proprietary reducers are available for larger diameter
conduits.
4.11 GMXS4 seismic test tool
Table 4-2: GMXS4 seismic test tool
The GMXC4 (available October 2016) is a battery operated, hand held test tool for the verification
of the seismic detectors. The GMXS4 is an essential part of the commissioning procedure, cus-
tomer demonstrations, and handovers. The tool works on both steel and concrete surfaces.
Operation of the test button starts a series of signals that are detected as an integration alarm by
the detector under test.
Place the test tool adjacent to the detector under test and press the test button. The detector
should respond with an alarm condition within 10 seconds.
More information to follow.