Design
6
45
Vanderbilt
Seismic Detectors Application Guide
I-200153-1
08.2016
6.10 Filing cabinet
A single GM7xx detector mounted externally provides adequate coverage for most filing cabinets.
Figure 6-18: Filing cabinet shows a suggested installation of a detector mounted externally at the
side of the document cabinet.
Figure 6-18: Filing cabinet
6.11 Gun cabinet
Depending on the construction and size of the gun cabinet, a single detector may be adequate for
a protection. For cabinets of a robust construction a second detector mounted on the door of the
cabinet may be required. Consider the accessories GMXP3, GMXP3Z & GMAS-6 for lock protec-
tion and additional security.
Figure 6-19: Gun cabinet shows a suggested installation of a detector mounted internally to the top
of the gun cabinet.
Figure 6-19: Gun cabinet