Get-Funcon Lisng
The PC can interrogate the LFD for specic informaon. The Get-Funcon packet
format consists of 9 bytes which is similar to the Set-Funcon packet structure.
Note that the “Value” byte is always = 000.
Get-Funcon Descripon:
Length:
Total Byte of Message excluding “CR”.
TV/DS ID
Identification for each of TV/DS (01~98; default is 01).
Command Type
Identify command type,
“g” (0x67h) : Get Command
“r” (0x72h) : Valid command Reply
“-“ (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code.
Value[1~3]:
Three bytes ASCII that defines the value.
CR
0x0D
Get-Funcon Format
Send: (Command Type=“g”)
Name Length ID Command Type Command Value1 Value2 Value3 CR
Byte
Count
1 Byte
2
Byte
1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
1
Byte
Bytes
order
1 2~3 4 5 6 7 8 9
Reply: (Command Type=“r” or “-”)
If the Command is valid, Command Type = “r
Name Length ID Command Type Command Value1 Value2 Value3 CR
Byte
Count
1 Byte
2
Byte
1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
1
Byte
Bytes
order
1 2~3 4 5 6 7 8 9
If the Command is NOT valid, Command Type = “-”
Name Length ID Command Type CR
Byte
Count
1 Byte 2 Byte 1 Byte 1 Byte
Bytes
order
1 2~3 4 5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ViewSonic ViewBoard IFP33 Series and is the answer not in the manual?

ViewSonic ViewBoard IFP33 Series Specifications

General IconGeneral
BrandViewSonic
ModelViewBoard IFP33 Series
CategoryTouchscreen
LanguageEnglish

Related product manuals