D-303973 PowerMaxExpress Installer's Guide 29
USER SETTING
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
5. DEFINE COMM
[installer code]
INSTALLER MODE
4. DEFINE PANEL
COMMUNICATING TEL # NOT DEFINED
DOWNLOADING DIAL ATTEMPT FAIL
DOWNLOAD OK DOWNLOAD FAILED
Displayed during
dialing process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
Dialing
OK
Dialing
failed
Download
OK
Download
failed
Displayed during
download process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by happy
(success) melody
9. DEFINE CUSTOM
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT
READY 00:00
P1 RDY 00:00
Non-Partition
mode
Partition
mode
WALK TEST
READY
(First display)
Figure 4.14 Start UL/DL
4.15 ENABLING/DISABLING PARTITIONS
This menu allows you to enable/disable Partition Mode.
Partitioning allows you to divide the system into a
maximum of three independently controllable areas. Each
area can be armed / disarmed separately.
When the partition feature is disabled, zones, user codes
and features will operate the same as in a regular
PowerMaxExpress unit. When partition is enabled, menu
displays are changed to incorporate the partition feature.
15. PARTITIONING
USER SETTING
ENTER CODE
1. NEW INSTL CODE
INSTALLER MODE
[inst. code]
<OK> TO EXIT
enable
disable
Note: Partitioning is an optional feature
WALK TEST
READY
(First display)
Figure 4.15 Partitioning
4.16 DEFINING THE ARMING STATION
This mode allows you to customize the MKP-160 2way
keyprox device through the control panel and adapt the
device characteristics and behavior to the requirements of
the particular user.
4.16.1 Tamper Type
Enabling the function will enable a tamper open / close
message.
Available options are: disable and enable.
4.16.2 Screen Saver
Enabling the function will turn off the display if no key is
pressed for more than several seconds.
Available options are: disable (ac) and enable.
4.16.3 Show AC Failure
Enable/disable AC failure indication on the keyprox device.
Available options are: disable and enable.

Table of Contents

Other manuals for Visonic POWERMAXEXPRESS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Visonic POWERMAXEXPRESS and is the answer not in the manual?

Visonic POWERMAXEXPRESS Specifications

General IconGeneral
BrandVisonic
ModelPOWERMAXEXPRESS
CategorySecurity System
LanguageEnglish

Related product manuals