48
EPG-SPRINT.
%
0
10
20
30
40
50
60
70
80
90
100
Ø
12
10
11
9
8
m /h
5.0
4.0
3.0
2.0
6.0
3
5.5
4.5
3.5
2.5
2.2
m
/h
4.0
3.0
2.0
1.0
0.5
0.4
0.3
0.2
0.1
1.5
P_01180
EPG
S
P
R
I
N
T
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
7 ELIMINATION OF FAULTS
SIHI_05019_ENG
DANGER
Incorrect maintenance/repair!
Danger to life and equipment damage.
Maintenance, repairs or the exchange of units or parts there of
must be carried out by trained personnel, outside the danger
areas.
7.1 WARNINGS E01-E04
The malfunction LED 13 fl ashes to indicate warnings. In addition, “Exx“ is shown alternately in LED display 19
(7-segment LED) (xx stands for the warning number). You may continue to work when a warning appears.
Warning No. Warning Cause Rectifi cation
E01 Atomizing air too low. Set set point cannot be
reached.
Causes:
Hose kinked / blocked.
Input air pressure too low.
Injector is not connected.
System cannot reach target
setting.
Check hoses and hose
laying.
Ensure that input pressure is
greater than 6 bar.
Connect injector.
Select smaller set point
value.
Example: feed air for
ED pump max. 3.5 Nm³/h.
19
13

Table of Contents

Other manuals for WAGNER EPG-SPRINT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-SPRINT and is the answer not in the manual?

WAGNER EPG-SPRINT Specifications

General IconGeneral
BrandWAGNER
ModelEPG-SPRINT
CategoryControl Unit
LanguageEnglish

Related product manuals