7.2 MALFUNCTIONS E11-E43
The fault LED 13 lights up to indicate faults. In addition, “Exx“ is shown alternately in the 7-segment LED display
19 (xx stands for the fault number). If a fault occurs, high-voltage, air etc. are immediately switched off. The user
can only continue to work once the fault has been remedied and acknowledged.
Fault numbers Faults Cause Rectifi cation
E11 Ground monitoring.
● The grounding cable is
interrupted.
● The gun is not connected.
● Check/replace gun cable.
● Check/replace gun.
● Connect the gun.
E12 No coil current/
cascade interrupt.
● The gun is not connected.
● Gun cable is interrupted.
● Cascade in gun is
interrupted --> defective.
● Connect the gun.
● Check/replace gun cable.
● Check/replace gun.
E13 Coil current too big. ● Cascade of the connected
gun is defective.
● Check/replace gun.
E14 Tribo current too
high.
● The Tribo current has
exceeded the upper limit
value of 12 µA.
ATEX guidelines do not
permit higher values.
● Reduce Tribo air.
● Reduce powder quantity.
E15-E17 High-voltage
generator error.
● Hardware defect. ● If problem persists,
contact Wagner Service
Team.
E20 Password error. ● The password for enabling
the device is not set or has
been lost.
● Inform Wagner service
center.