38 HC920•HC940•HC960
Description of unit
3.8 Technical data for electric HC units
HC 920 HC 940 HC 940-SSP HC 960 HC 960-SSP
Voltage
230 V~, 50 Hz: R R R
400 V, 50 Hz, V3~: R R
Fuse protection
16 A: R R R R
Power cord
3 x 2.5 mm
2
– 6 m: R R R
5 x 2.5 mm
2
– 6 m: R R
Capacity
3.1 kW: R R R
5.5 kW: R R
Max operating pressure
22.8 MPa (228 bar): R R R R R
Maximum volume ow
5.5 l/min: R
6.6 l/min: R R
10 l/min: R R
Volume ow at 12 MPa (120 bar)
4.8 l/min: R
5.2 l/min: R R
10 l/min: R R
Max. size of tip with a spray gun
0.043 inch – 1.10 mm: R
0.052 inch – 1.30 mm: R R
0.056 inch – 1.42 mm: R R
Max. temperature of the coating material
43° C: R R R R R
Max. Viscosity
40.000 mPa·s: R
50.000 mPa·s: R R
65.000 mPa·s: R R
Filter insert (standard equipment)
5 Maschen: R
0 Maschen: R R R R
Weight:
83 kg R R
84.5 kg R
100 kg R
103 kg R
Hydraulic oil lling quantity
4.7 l ESSO Nuto H 32: R R R R R
Max. tire pressure
0.2 MPa (2 bar): R R R R R
Special high-pressure hose
DN 10 mm, 15 m, connection thread NPSM 3/8: R R
DN 13 mm, 15 m, connection thread NPSM 1/2: R R R
DN 19 mm, 15 m, connection thread NPSM 3/4: R R R
Hose whip
DN 10 mm, 2,5 m, connection thread NPSM 3/8: R R R
Dimensions L x W x H
1160 x 955 x 655 mm: R
1185 x 955 x 655 mm: R R
1200 x 955 x 655 mm: R R
Max. sound pressure level:
77 dB (A)* R
80 dB (A)* R R
88 dB (A)* R R
*Placeofmeasurement:1mdistancefromunitand1.60mabovereverberantoor,12MPa(120bar)operatingpressure.