MACHINE OPERATION
86037880 CHARIOT EXTRACTOR 01/16/07
3-12
FILLING SOLUTION TANK
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, turn off machine
and remove key.
1. Turn the machine power off.
2. Remove solution cover.
3. Fill the solution tank with clean water, leaving
enough room for the required amount of
cleaning solution. The solution tank capacity
filled to fill inlet is 25 gallons (95 liters). The
water must not be hotter than 140° F (60°C) to
prevent damage to the tank.
4. Measure the chemical into the solution tank.
Liquid chemicals should be added to the solution
tank after filling with water. Dry chemicals
should be thoroughly mixed before being added
into solution tank. Commercially available, high
alkaline floor cleaners are suitable for use in the
solution system.
NOTE: Read the chemical manufacturers
recommended proportion instructions.
4. Replace solution tank cover.
Flammable materials
can cause an
explosion or fire. Do not use flammable
materials in the tanks.
NORMAL SCRUBBING
Plan the scrubbing pattern in advance.
For efficient operation, the runs should be the
longest possible without turning, stopping, or raising
or lowering scrub deck. The longest track is around
the perimeter of the area to be cleaned and a
collapsing rectangle pattern is most efficient.
In order to achieve the best possible results, the
area which is to be cleaned should be swept before
scrubbing. Large debris, strings and wire must be
removed to prevent being caught in brushes.
If the machine is allowed to stand in neutral with the
scrub deck down for more than 2 seconds, the
solutions flow stops and brush motors stop. When
forward travel is resumed, the solution flow and the
scrub brush motors will continue. Overlap the brush
path and avoid transporting over previously cleaned
areas.
RECOMMENDED SCRUBBING PATH