29
F2.00
V/F curve setup
0 straight V/F curve:
10
1 multiple-point V/F curve:
2 square V/F curve 1 1.5 time power:()
3 square V/F curve 2 2.0 time power:()
F2.01 V/F frequency point
F1
0.00Hz F2~
0.01Hz
0.00Hz
F2.02
V/F voltage point
V1
0.0% V2~
0.1%
0.0%
F2.03
V/F frequency point
F2
F1 F3~
0.01Hz
F2.04 V/F voltage point V2
V1 V3~
0.1%
F2.05 V/F frequency point
F3
F2 rated motor frequency~
0.01Hz
F2.06 V/F voltage point V3
V2 100.0%~
0.1%
F2.07
Torque boost
0.0% automatic torque boost:
0.1%
model
dependent
F2.08
Cutoff frequency of
torque boost
0 Maximum F0.11~
0.01Hz
50.00Hz
F2.09
Slip compensation
coefficient
0 200%~
1%
0%
○
F2.10
Automatic voltage
regulating (AVR)
selection
0 disabled:
12
1 active:
2 disabled only at the time of deceleration:
F2.11
Oscillation
suppression gain
0 100~
1
15
F2.12
Carrier frequency
1.0 15kHz~
0.1kHz model
dependent
○
○
25.00Hz
50.00Hz
50.0%
100.0%
○
○
V/F Control Parameters
Group
F2
0.1 20.0% manual torque boost~:
Chapter 5 Function Parameter Table
Factory default
value
Function
code
Name
Setup range
Minimum unit
Modif-
ication
F2.13
Carrier frequency
adjustment selection
0 Fixed PWM carrier frequency
temperature adjustment disabled
:,
1 Random PWM carrier frequency
temperature adjustment disabled
:,
2 Fixed PWM carrier frequency
temperature adjustment actived
:,
3 Random PWM carrier frequency
temperature adjustment actived
:,
1
2
○