59
Group F8 Fault and Protection
50 200%
0.0 20.0s
0
1
The parameter set the inverter protective action mode when it
is overload or overheat.
0 The inverter locks output immediately . When it is overload
or overheat, the inverter locks output and the motor coasts to
stop .
1 Limitative current running alarm . When it is overload
or overheat , the inverter is limitative current mode,
and the inverter might reduce the output frequency to decrease
the load current
:(
running in a
at this time.
30.0 100.0%
The value is equal to motor rated current/inverter rated current .
When the inverter output current exceeds F8.03 multiply the
inverter rated output current for a certain time , the inverter
reports motor overload fault .
110 200%
120 150%
Select the protection point for the stall over current function.
When the value is exceeded , the inverter starts executing the
protection function for stall over current .
Select the protection point for the stall over voltage .
When the value is exceeded , the inverter starts executing the
protection function for stall over voltage .
function
The reference for this value is the inverter rated current .
When the inverter detects that the output current exceeds
the parameter F8.00 ,
it outputs pre-warning signal from OC or relay,
.
corresponding current of continuously
after the
delayed time of F8.01
When restart after power-off is enabled ,inverter is on the
running state before power cut. Then the inverter will start
automatically after the setup waiting time (it is set by F8.07)
when power-on .During the restart waiting time ,
even though there inputs run command, if there
inputs stop command , it will finish the restart waiting state .
the inverter
won’t start,
03
0.1 100.0s
When the inverter selects fault automatical reset , it is used to set
the times of automatical reset .If the value is exceeded , the
inverter will stop because of failure and wait for maintenance .
The waiting time of the inverter from the fault alarm to automatical
reset .
Fault meaning
Fault code
E.1
E.OC1
E.OC2
E.OC3
E.OU1
E.OU2
E.OU3
E.OU4
E. LU
E.OL1
E.OL2
E. LF
E. OH
E. EF
E. CE
E. GF
E.2
E.3
E.4
E.5
E.6
E.7
E.8
--
110%
2.0S
0
F8.00
F8.01
F8.02
100%
F8.03
150%
F8.04
130%
F8.05
F8.08
F8.09
F8.11
F8.12
F8.10
0
1.0S
Chapter 6 Parameter Description
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Factory
default value
Setup range
Setup range
Setup range
Setup range
Setup range
Setup range
Setup range
Setup range
Inverter overload
pre-warning
Inverter overload
pre-warning delayed time
Overload Overheat
protective action mode
inverter locks output
limitative current running alarm()
Motor overload
protection codfficient
Stall protection
coefficient over current
Stall protection
coefficient over current
Fault automatic
reset times
Fault automatic reset
interval time
First time fault type
Second time fault type
Third time fault type
0 no fault
1 Inverter unit protection
2 Acceleration over current
3 Deceleration over current
4 Constant speed over
current
5 Acceleration over voltage
6 Deceleration over voltage
7 Constant speed over
voltage
8 Stop over voltage
9 Running under voltage
10 Inverter overload
11 Motor overload
12 Phase loss output
13 Inverter overheat
14 External equipment fault
15 Communication fault
16 Output grounding
17 CPU interference
18 Current detect fault
19 EEPROM read-write fault
20 Phase loss input
21 PID feedback
disconnection
22 Reserved
23 Reserved
0
F8.06
Factory
default value
Setup range
0 no action
1 action
Restart setup after
power-off
Factory
default value
1.0S
F8.07
0.1 10.0s
Setup range
Restart waiting time
after power-off