72
The Communication parameter add.definition of
Read-write function code parameter
Add.rule
e.g. function code F3.12 is not saved to EEPROM , only to modify RAM, the Add. is expressed as 030C.
Note
Use the function code group number and sequence number to express the rule
high-order F0 FD:~
low-order 00 FF:~
e.g. F3.12, the Add is expressed as F30C:;
Some parameters can only be read but cannot be modified ,some parameters cannot be modified when the inverter is
in running status; when modify it ,you should notice the setup range ,unit and correlative description of parameters .
In addition , since EEPROM is saved frequently , its will be reduced, thus, some function code needn't to be saved
and you just need to modify the RAM value in the communication mode. To realize the function , you need to change
of function code address into 0.
life
the
high-order F
Correlative function code address is expressed as following
high-order 00 0D:~
low-order 00 FF:~
This part is the communication, it is used to control the inverter and inverter status and the
correlative parameter setting .
content of running of
FV.00 Output frequency
Output current
Running rotation speed
Total running time
PID setup(read or write, write may change the PID setup value of communication setting)
PID feedback(read or write, write may change the PID feedback value of communication setting)
Setup frequency(read or write, write may change the setup value of communication setting)
FV.01
FV.02
FV.03
FV.13
FV.14
FV.25
Coding
Monitor parameter Group FV
Description
1000H
1001H
1002H
1003H
l
ll
ll
l
l
ll
ll
l
ll l
100DH
100EH
1019H
Add.
0003:Forward rotation Jog running
0004:Inverse rotation Jog running
0006:inverter fault
0001:Forward rotation running
0002:Inverse rotation running
0005:DC brake
Read the status of the inverter (only-read)
Data
0007:stop
Add.
3000H
Control command input into the inverter:(only-write)
0001:Forward rotation running
0002:Inverse rotation running
0003:Forward rotation Jog
0004:Inverse rotation Jog
0005:coast stop
0006:deceleration stop
0007:fault reset
Data
CMD Add.
2000H
Chapter 7 EH600 Communication Protocol and Description of Communication