(2) Installation location
Free of corrosive or explosive gases.
Well-ventilated and free of dust and moisture.
Ambient temperature of 0° to 5C.
Relative humidity (r.h.) of 20 to 80% with no condensation.
Accessible for inspection and cleaning.
(3) Concentricity
Please use coupling when connecting to machine; keep the shaft center of servo motor and
machine at the same line. It should be accord to the following diagram when installing the
servo motor.
Note:
If the concentricity is not enough, it will cause the vibration and bearing damage.
When installing the coupler, prevent direct impact to the shaft. This can damage the
encoder mounted on the shaft end at the opposite side of the load.
(4) Installation direction
MS series servo motors can be installed either horizontally or vertically.
Measure it at 4 places of the circle, the difference should be below
0.03mm. (Rotate with the shaft coupler)
Measure it at 4 places of the circle, the difference should be below
0.03mm. (Rotate with the shaft coupler)

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals