63
Table 3: output signal distributions
Output terminal parameters
Servo drive
Range
P5-28~P5-38
All the
models
n.0000~n.0003
n.0010~n.0013
Table 4: the default settings of output terminals
Terminal
SO1
SO2
SO3
Function
/COIN
/ALM
/S-RDY
►► Alarm information
Code
Explanations
Reasons
Solution
E-001
Program damage
Cannot pass the program
self-test
Re-download the program,
contact us
E-002
Parameter
damage
Cannot pass the parameter
self-test
Re-power on the drive or
contact us
E-003
bus overvoltage
Grid voltage is too high or
not connect to regenerative
resistor, regenerative
resistor is broken or value
to large
Check the grid and regenerative
E-004
Bus under voltage
Grid voltage is too low
Check the grid
E-005
Regenerative
resistor error
Regenerative resistor is not
functional
Check the regenerative resistor
E-006
Module
temperature too
Running for long time with
large load will cause
module temperature too
Use small load, enhance the
ventilation, check if the fan is
working when servo is enable;

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals