71
Forced Servo enables (F1-05)
Software enable (F1-05
or communication)
Bus enable (the model
support movement bus)
F1-05 = 0: cancel the enable, return to bb status.
F1-05 = 1: forced enable, servo is in RUN status.
Alarm operation (E-XX)
The alarm code will show when there is error in the drive. Set F0-00=1 to reset the alarm. If
the servo is OFF caused by alarm, it is no need to reset the alarm.
Note: please find out the alarm reason before reset the alarm.
5-5. Change motor code
Note:
(1) One servo drive can match several servo motors with same power level. Before
using the servo system, please make sure the motor code on the servo motor label is
the same to P0-33.
(2) If the motor code setting is error, it will show E-310, please clear the alarm through
F0-00, then set the correct code.