71
Forced Servo enables (F1-05)
Parameter
Signal
name
Set
Meaning
Modify
Effective
P0-03
Enable
mode
0
Not enable
Servo OFF
At once
1 (default)
I/O enable /S-ON
2
Software enable (F1-05
or communication)
3
Bus enable (the model
support movement bus)
P0-03=2
F1-05 = 0: cancel the enable, return to bb status.
F1-05 = 1: forced enable, servo is in RUN status.
Alarm operation (E-XX)
The alarm code will show when there is error in the drive. Set F0-00=1 to reset the alarm. If
the servo is OFF caused by alarm, it is no need to reset the alarm.
Note: please find out the alarm reason before reset the alarm.
5-5. Change motor code
Note:
(1) One servo drive can match several servo motors with same power level. Before
using the servo system, please make sure the motor code on the servo motor label is
the same to P0-33.
(2) If the motor code setting is error, it will show E-310, please clear the alarm through
F0-00, then set the correct code.

Other manuals for Xinje DS3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3 Series and is the answer not in the manual?

Xinje DS3 Series Specifications

General IconGeneral
BrandXinje
ModelDS3 Series
CategoryServo Drives
LanguageEnglish

Related product manuals