15
Relative humidity < 90% (no condensation)
2.Product installation
2-1. Servo drive
The DS3/DS3E series servo drives are base-type servo drive. Incorrect installation will cause
problems. Follow the installation instructions below.
1)Storage temperature
Store the servo drive within -20~+85℃, as long as it is stored with the power cable
disconnected.
2)Installation site
Please install the servo drive as the following items.
Installation in a
Control Panel
Design the control panel size, unit layout, and cooling method so
the temperature around the servo drives does not exceed 50°C.
Installation Near a
Heating Unit
Minimize heat radiated from the heating unit as well as any
temperature rise caused by natural convection so the temperature
around the servo drives does not exceed 50°C.
Installation Near a
Source of Vibration
Install a vibration isolator beneath the servo drive to avoid
subjecting it to vibration.
Installation at a Site
Exposed to Corrosive
Corrosive gas does not have an immediate effect on the servo
drives, but will eventually cause electronic components and