EasyManuals Logo

Yaesu FT-891 Technical Supplement

Yaesu FT-891
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
FT-891 Technical Supplement
Alignment
ALIGNMENT-7
RF AGC Adjustment
Set the VFO-A frequency to 14.200 MHz in the
CW-USB mode.
Set the following controls as indicated:
[
IPO
]
: ON
[
ATT
]
: OFF
[
AGC
]
: AUTO
[
RF GAIN
]
: Fully clockwise
Connect the RF Signal Generator to the ANT
jack, then set the output level to +76 dBμ at the
14.200 MHz.
Connect the Digital DC voltmeter (high-Z) to
TP1016 on the MAIN Unit.
Adjust VR1001 on the MAIN Unit so that the
Digital DC voltmeter reading is “1.2 V ±0.2 V”.
Press and hold in the
[
F
]
key to save the new
setting and exit the alignment mode.
VR1001TP1016