JOHNSON CONTROLS
16
Form 150.63-NM9
Issue date: 5/20/2021
SECTION 2 PRODUCT DESCRIPTION
driven, and positioned for vertical air discharge. The
fan guards are constructed of heavy-gauge, rust-resis-
tant, PVC (polyvinyl chloride)-coated steel wire.
Motors
The fan motors are totally enclosed air-over (TEAO),
squirrel-cage type, current protected. They feature ball
bearings that are double-sealed and permanently lubri-
cated.
Microcomputer Control Center
All controls are contained in a NEMA 3R/12 cabinet
and include Liquid Crystal Display (LCD) with Light
Emitting Diode (LED) backlighting for outdoor view-
ing. The display includes the following features:
Two display lines
Twenty characters beforeline
Display/Print
Color coded 12-button non-tactile keypad with sec-
tions for display and print of typical information:
Suction temperatures (optional)
Ambient temperature
System pressures (each circuit)
Operating hours and starts (each compressor)
Print calls up to the liquid crystal display
Operating data for the systems
History of fault shutdown data for up to the last
six fault shutdown conditions.
An RS-232 port, in conjunction with the press-to-
print button, is provided to allow hard copy print-
outs through a separate printer (by others).
Entry
This section is used to enter setpoints or modify system
values.
Setpoints
Updating can be performed to:
Suction pressure setting
Suction pressure control zone
Remote reset temperature range
Set daily schedule/holiday for start/stop
Manual override for servicing
Low and high ambient cutouts
Number of compressors
Low suction pressure cutout
High discharge pressure cutout
Anti-recycle timer (compressor start cycle time)
Anti-coincident timer (delay compressor starts)
Unit
This section is used to:
Set clock
Set options
Set unit option
Set unit control for Discharge Air Temperature Control
or for Suction Pressure Control (requires Suction Pres-
sure Transducers) is standard.
Unit On/Off Switch
The microprocessor control center is capable of
display ing the following:
Suction temperatures (optional)
Low ambient temperature cutout setting
English or metric data
Suction pressure cutout setting
Each system suction pressure
System discharge pressure
Discharge air temperature reset through a YORK
ISN DDC or Building Automation System (by
others) using the following:
A pulse-width modulated (PWM) input as
standard
A 4 mA to 20 mA or 0 VDC to 10 VDC input,
or contact closure with the optional B.A.S.
interface option