User Manual 3PH HYD5000-HYD20000-ZSS
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1. of 16/03/2021 - Application: GID
75/138
05
00
Denmark
33
Ukraine
01
TR322
35
00
Mexico
LV
06
00
Greece
Continent
38
Wide-Range-60Hz
01
island
39
Ireland EN50438
07
00
Netherlands
40
00
Thailand
PEA
08
00
Belgium
01
MEA
09
00
UK
G99
42
00
LV-Range-50Hz
01
G98
44
00
South Africa
10
00
China
46
00
Dubai
DEWG
01
Taiwan
01
DEWG MV
11
00
France
107
00
Croatia
01
FAR Arrete23
108
00
Lithuania
Table 17 - List of country codes
7.2.4. Setting of input channel
Input Channel Config
Input
Channel1
Bat input 1
Up↑
Down↓
Bat input 2
OK
Not use
Input
Channel2
Bat input 1
Up↑
Down↓
Bat input 2
OK
Not use
Input
Channel3
PV input 1
Up↑
Down↓
PV input 2
OK
Not use
Input
Channel4
PV input 1
Up↑
Down↓
PV input 2
OK
Not used
In the case of a single Pylontech battery tower, set the inputs according to the channel
populated:
Input channel 1 → BAT input 1 (if the channel populated is no. 1)
Input channel 2 → Not Used
In the case of a single WeCo battery tower, set the inputs by populating both channels:
Input channel 1 → BAT input 1
Input channel 2 → BAT input 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZCS Azzurro 3PH HYD15000 ZSS and is the answer not in the manual?

ZCS Azzurro 3PH HYD15000 ZSS Specifications

General IconGeneral
BrandZCS
ModelAzzurro 3PH HYD15000 ZSS
CategoryInverter
LanguageEnglish

Related product manuals