Printer Configuration and Adjustment
Calibrate the Ribbon and Media Sensors Manually
106
P1056468-002 7/3/13
Calibrate the Ribbon and Media Sensors Manually
Use the calibration procedure in this section when necessary to calibrate the printer based on
the media and ribbon that you are currently using. Manual calibration is recommended
whenever you are using pre-printed labels (or label backing) or if the printer will not correctly
auto calibrate.
For issues that may be resolved by sensor calibration, see Printing Issues on page 136.
For a summary of the options for initiating calibration, see Media and Ribbon Sensor
Calibration on page 94.
To perform sensor calibration, complete these steps:
1. With the printer in the Ready state, initiate media and ribbon calibration through the
printers display:
a. Navigate to the following parameter. See Control Panel Display on page 17 for
information about using the control panel.
b. Press RIGHT SELECT to select START.
The printer does the following:
•The STATUS light and SUPPLIES light flash yellow once.
•The PAUSE light blinks yellow.
The control panel displays:
LOAD BACKING
Important • Follow the calibration procedure exactly as presented. All of the steps must be
performed even if only one of the sensors requires adjustment. You may press and hold
CANCEL at any step in this procedure to cancel the process.

Table of Contents

Other manuals for Zebra 105SL Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra 105SL Plus and is the answer not in the manual?

Zebra 105SL Plus Specifications

General IconGeneral
BrandZebra
Model105SL Plus
CategoryPrinter
LanguageEnglish

Related product manuals