DataWedge
89
• LCD Mode - Enables or disables LCD mode. LCD mode enhances the ability of the imager to read bar
codes from LCD displays such as cellphones.
• Disable - Disables the LCD mode (default).
• Enable - Enables LCD mode.
• HW Engine Low Power Timeout -
• Picklist - Allows the imager to decode only the bar code that is directly under the cross-hair/reticle (+) part
of the pattern. This feature is useful in applications where multiple bar codes may appear in the field of
view during a decode session and only one of them is targeted for decode.
• Disabled – Disables Picklist mode. Any bar code within the field of view can be decoded (default).
• Enabled – Enables Picklist mode so that only the bar code under the projected reticle can be decoded.
• Poor Quality Decode Effort - Enable poor quality bar code decoding enhancement feature.
• Aim Timer - Sets the maximum amount of time that aiming remains on (0 - 60,000 ms in increments of 100
ms). A value of 0 sets the aim to stay on indefinitely (default - 500) (Imager only).
• Aim Type - Set the aiming usage.
• Trigger - A trigger event activates decode processing, which continues until the trigger event ends or
a valid decode occurs (default).
• Timed Hold - A trigger pull and hold activates the laser for aiming, which continues until the trigger is
released, a valid decode, or the decode session time-out is expired.
• Timed Release - A trigger pull activates the laser for aiming, which continues until a valid decode or
the remaining decode session time has expired.
• Press and Release - A trigger pull and release activates the laser for aiming, which continues until a
trigger is pressed again, a valid decode, or the decode session time-out is expired.
• Continuous Read - When the imager detects an object in its field of view, it triggers and attempt to
decode.
• Beam Timer - Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments
of 100 ms). A value of 0 sets the reader to stay on indefinitely (default - 5000).
• Different Symbol Timeout - Controls the time the scanner is inactive between decoding different
symbols. Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
• Same Symbol Timeout - Controls the time the scanner is inactive between decoding same symbols.
Programmable in 500 msec increments from 0 to 5 seconds. The default is 500 msec.
Scan Params
Allows the configuration of Code ID and decode feedback options.
• Code ID Type - A Code ID character identifies the code type of a scanned bar code. This is useful when
the reader is decoding more than one code type. Select a code ID character to insert between the prefix
and the decoded symbol.
• Code ID Type None - No prefix (default)
• Code ID Type AIM - Insert AIM Character prefix.
• Code ID Type Symbol - Insert Symbol character prefix.
• BT Disconnect On Exit - Bluetooth connection is disconnected when data capture application is closed
(RS6000 only).
• Connection Idle Time - Set connection idle time. The Bluetooth connection disconnects after being idle
for set time (RS6000 only).
• Decode Haptic Feedback - Enable the device to vibrate upon a good decode (default - enabled).